Home Page   |   Login   |   Site Map   |   Türkçe

 

 

 
New Page 1

REVERSE OSMOSIS UNITS

 

 

TAF Reverse Osmosis Units are used to remove the dissolved salts from pressurized water by the aid of a semi permeable membrane. While treated water passes through the membranes the dissolved solids, particles and organic matters that cannot pass through the membrane are send to drainage as waste.

 

Reverse Osmosis Unit Equipments

 

 

  1. 1 micron Prefiltre
  2. High pressure pump and control panel
  3. Membrane and membrane housing
  4. Manometer, Pressure Switches and Flowmeters
  5. Control instruments (pH Meter, ORP Meter, Conductivity meter etc.)
  6. Automatic Inlet Selenoid and Autoflush System

 

Applications

 

 

  • Drinking and usage water production from city, well and Ground water (Houses, Sites, Hotels, Restaurant, Municipalities etc.)
  • Drinking and usage water production from seawater (Houses, Sites, Hotels, Restaurant, Municipalities etc.)
  • Process water production (Textile, food and beverage, cosmetics, medicine, electronic, concrete, energy, health and media sectors etc.)
  • Boiler unit applications

 

750lt/h RO System

6m3/h RO System

15m3/h RO System

17m3/h RO System

45m3/h RO System

50m3/h RO System

 

 

High Ion Removal Reverse Osmosis Units

 

 

High ion removal reverse osmosis units are prefered for city, well and ground water and the working pressure is between 13-30 bar. 

 

 

MODEL
FLOW
(m3/h)
MEMBRANE
ION
REDUCTION
MAX. TDS
TYPE
PIECE
2.5” SERIES
TAF®ROR2-100
0,10
AG 2540
1
%99.5-99
10.000 mg/l
TAF® ROR2-200
0,20
AG 2540
2
%99.5-99
10.000 mg/l
4”  R SERIES
TAF® ROR4-250
0,25
AG 4040
1
%99.5-99
10.000 mg/l
TAF® ROR4-500
0,50
AG 4040
2
%99.5-99
10.000 mg/l
4” SERIES
TAF® ROC4-250
0,25
AG 4040
1
%99.5-99
10.000 mg/l
TAF® ROC4-500
0,50
AG 4040
2
%99.5-99
10.000 mg/l
TAF® ROC4-750
0,75
AG 4040
3
%99.5-99
10.000 mg/l
TAF® ROC4-1000
1,00
AG 4040
4
%99.5-99
10.000 mg/l
TAF® ROC4-1250
1,25
AG 4040
5
%99.5-99
10.000 mg/l
TAF® ROC4-1500
1,50
AG 4040
6
%99.5-99
10.000 mg/l
4” H SERIES
TAF® ROC4H-2000
2,00
AG 4040
8
%99.5-99
10.000 mg/l
TAF® ROC4H-2250
2,25
AG 4040
9
%99.5-99
10.000 mg/l
TAF® ROC4H-2500
2,50
AG 4040
10
%99.5-99
10.000 mg/l
TAF® ROC4H-3000
3,00
AG 4040
12
%99.5-99
10.000 mg/l
TAF® ROC4H-3750
3,75
AG 4040
15
%99.5-99
10.000 mg/l
TAF® ROC4H-4500
4,50
AG 4040
18
%99.5-99
10.000 mg/l
TAF® ROC4H-5250
5,25
AG 4040
21
%99.5-99
10.000 mg/l
TAF® ROC4H-6000
6,00
AG 4040
24
%99.5-99
10.000 mg/l
8” SERIES
TAF® ROC8-6
6-7
AG 8040
6
%99.5-99
10.000 mg/l
TAF® ROC8-9
9-10
AG 8040
9
%99.5-99
10.000 mg/l
TAF® ROC8-12
12-13
AG 8040
12
%99.5-99
10.000 mg/l
TAF® ROC8-15
15-17
AG 8040
15
%99.5-99
10.000 mg/l
TAF® ROC8-18
18-19
AG 8040
18
%99.5-99
10.000 mg/l
TAF® ROC8-20
20-22
AG 8040
20
%99.5-99
10.000 mg/l
TAF® ROC8-25
24-26
AG 8040
24
%99.5-99
10.000 mg/l
TAF® ROC8-30
30-33
AG 8040
30
%99.5-99
10.000 mg/l
TAF® ROC8-36
36-40
AG 8040
36
%99.5-99
10.000 mg/l
TAF® ROC8-40
40-42
AG 8040
40
%99.5-99
10.000 mg/l
TAF® ROC8-45
45-47
AG 8040
45
%99.5-99
10.000 mg/l
TAF® ROC8-48
48-53
AG 8040
48
%99.5-99
10.000 mg/l
TAF® ROC8-54
54-56
AG 8040
54
%99.5-99
10.000 mg/l
TAF® ROC8-60
60-62
AG 8040
60
%99.5-99
10.000 mg/l
TAF® ROC8-72
72-80
AG 8040
72
%99.5-99
10.000 mg/l
TAF® ROC8-80
80-85
AG 8040
80
%99.5-99
10.000 mg/l
TAF® ROC8-90
90-95
AG 8040
90
%99.5-99
10.000 mg/l
TAF® ROC8-96
96-100
AG 8040
96
%99.5-99
10.000 mg/l
TAF® ROC8-108
108-119
AG 8040
108
%99.5-99
10.000 mg/l

 

Low Energy Reverse Osmosis Units

 

 

Low energy reverse omosis units are prefered at city, well and ground water and the working pressure is between 7-10 bar. 

 

 

MODEL
FLOW
(m3/h)
MEMBRANE
ION
REDUCTION
MAX. TDS
(mg/l)
TYPE
PIECE
2.5” SERIES
TAF®ROR2L-100
0,10
AK 2540
1
%99-98
2000 mg/l
TAF® ROR2L-200
0,20
AK 2540
2
%99-98
2000 mg/l
4”  R SERIES
TAF® ROR4L-250
0,25
AK 4040
1
%99-98
2000 mg/l
TAF® ROR4L-500
0,50
AK 4040
2
%99-98
2000 mg/l
4” SERIES
TAF® ROC4L-250
0,25
AK 4040
1
%99-98
2000 mg/l
TAF® ROC4L-500
0,50
AK 4040
2
%99-98
2000 mg/l
TAF® ROC4L-750
0,75
AK 4040
3
%99-98
2000 mg/l
TAF® ROC4L-1000
1,00
AK 4040
4
%99-98
2000 mg/l
TAF® ROC4L-1250
1,25
AK 4040
5
%99-98
2000 mg/l
TAF® ROC4L-1500
1,50
AK 4040
6
%99-98
2000 mg/l
4” H SERIES
TAF® ROC4HL-2000
2,00
AK 4040
8
%99-98
2000 mg/l
TAF® ROC4HL-2250
2,25
AK 4040
9
%99-98
2000 mg/l
TAF® ROC4HL-2500
2,50
AK 4040
10
%99-98
2000 mg/l
TAF® ROC4HL-3000
3,00
AK 4040
12
%99-98
2000 mg/l
TAF® ROC4HL-3750
3,75
AK 4040
15
%99-98
2000 mg/l
TAF® ROC4HL-4500
4,50
AK 4040
18
%99-98
2000 mg/l
TAF® ROC4HL-5250
5,25
AK 4040
21
%99-98
2000 mg/l
TAF® ROC4HL-6000
6,00
AK 4040
24
%99-98
2000 mg/l
8” SERIES
TAF® ROC8L-6
6-7
AK 8040
6
%99-98
2000 mg/l
TAF® ROC8L-9
9-10
AK 8040
9
%99-98
2000 mg/l
TAF® ROC8L-12
12-13
AK 8040
12
%99-98
2000 mg/l
TAF® ROC8L-15
15-17
AK 8040
15
%99-98
2000 mg/l
TAF® ROC8L-18
18-19
AK 8040
18
%99-98
2000 mg/l
TAF® ROC8L-20
20-22
AK 8040
20
%99-98
2000 mg/l
TAF® ROC8L-25
25-27
AK 8040
25
%99-98
2000 mg/l
TAF® ROC8L-30
30-33
AK 8040
30
%99-98
2000 mg/l
TAF® ROC8L-36
36-39
AK 8040
36
%99-98
2000 mg/l
TAF® ROC8L-40
40-42
AK 8040
40
%99-98
2000 mg/l
TAF® ROC8L-45
45-47
AK 8040
45
%99-98
2000 mg/l
TAF® ROC8L-48
48-53
AK 8040
48
%99-98
2000 mg/l
TAF® ROC8L-54
54-56
AK 8040
54
%99-98
2000 mg/l
TAF® ROC8L-60
60-62
AK 8040
60
%99-98
2000 mg/l
TAF® ROC8L-72
72-78
AK 8040
72
%99-98
2000 mg/l
TAF® ROC8L-80
80-85
AK 8040
80
%99-98
2000 mg/l
TAF® ROC8L-90
90-95
AK 8040
90
%99-98
2000 mg/l
TAF® ROC8L-96
96-100
AK 8040
96
%99-98
2000 mg/l
TAF® ROC8L-108
108-119
AK 8040
108
%99-98
2000 mg/l

 

Seawater Reverse Osmosis Units

 

 

Seawater Reverse Osmosis Units are used at well waters with high salinity levels (>10.000mg/l TDS) and at seawater applications. The working pressure for system is between 30-65 bar.

 

 

MODEL
FLOW
(m3/h)
 
MEMBRANE
ION
REDUCTION
MAX. TDS
(mg/l)
TYPE
PIECE
4” SERIES
TAF® SW-ROC4-3
3
AD 4040
1
%99.6-99.2
45.000
TAF® SW-ROC4-6
6
AD 4040
2
%99.6-99.2
45.000
TAF® SW-ROC4-9
9
AD 4040
3
%99.6-99.2
45.000
TAF® SW-ROC4-12
12
AD 4040
4
%99.6-99.2
45.000
TAF® SW-ROC4-18
18
AD 4040
6
%99.6-99.2
45.000
MODEL
 
FLOW
(m3/h)
 
MEMBRANE
ION
REDUCTION
MAX. TDS
(mg/l)
8” SERIES
TAF® SW-ROC8-25
25
AD 8040
2
%99.6-99.2
45.000
TAF® SW-ROC8-35
35
AD 8040
3
%99.6-99.2
45.000
TAF® SW-ROC8-50
50
AD 8040
4
%99.6-99.2
45.000
TAF® SW-ROC8-75
75
AD 8040
6
%99.6-99.2
45.000
TAF® SW-ROC8-100
100
AD 8040
8
%99.6-99.2
45.000
TAF® SW-ROC8-125
125
AD 8040
10
%99.6-99.2
45.000
TAF® SW-ROC8-150
150
AD 8040
12
%99.6-99.2
45.000
TAF® SW-ROC8-200
200
AD 8040
16
%99.6-99.2
45.000
TAF® SW-ROC8-250
250
AD 8040
20
%99.6-99.2
45.000
TAF® SW-ROC8-300
300
AD 8040
24
%99.6-99.2
45.000
TAF® SW-ROC8-400
400
AD 8040
35
%99.6-99.2
45.000
TAF® SW-ROC8-500
500
AD 8040
42
%99.6-99.2
45.000

 

 

SEAWATER
RECOVERY RATE
AEGEAN-MEDITERRANEAN
 (38-43.000 mg/l)
%30-35
MARMARA (22.000 mg/l)
%40-45
BLACK SEA (18.000 mg/l)
%45-50

 

 

PLEASE CONTACT OUR FIRM FOR REVERSE OSMOSIS APPLICATIONS.

 

 
  PRINT TOP HOME PAGE BACK

 
 
 
    Copyright © 2008 Teknik Arıtma